Dual chamber waste incinerator manufacturers

Email:sales@hiclover.com|Tel:+86-25-8461 0201

Scrubber is air pollution control devices that use liquid to remove particulate matter 
or gasses from exhaust or flue gas steam. This atomized liquid (water) entrains particles 
and pollutant gases in order to effectively wash them out of the gas flow.  
Scrubber must be very multi-disciplinary with ability to remove solids, mist and gasses 
simultaneously while also providing cooling. 

Model

YD-100

Picture

 

Burning Rate

Average 100 kgs/hour

Feed Capacity

Average 200 kgs

Primary Combustion Chamber

1200 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.9Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

14--28 kg/hour

Gas Consumption (Natural Gas)

10--32.2 m3/hour

Internal Dimensions

130 x 100 x 90cm (primary chamber)

External Dimensions

220 x 180 x 360cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

300 Liters

Door Opening

55 x 80cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

6300 kgs

Operation Technical Specifications

Primary Chamber Temperature

800-1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal

Water saving system with re-circulating system and cooling tower.
Water treatment unit to treat the water used in Wet Scrubber before opening it into main drain.  
System has settling tank with minimum thickness of 3mm.
Circular Mild Steel / Stainless steel with minimum thickness 3mm, self-supported flange section chimney and should have suitable door/window at the base for cleaning. 
Proper port for taking exhaust gases sample to monitor emission levels as per international 
standards provided with a cover to be opened and closed when needed without affecting the function of chimney. 
Chimney should have height of at-least 15 meters from ground level.
Electrical Control:
PLC based control box with hinged sealed door, pre-installed control circuitry should be 
rugged enough to withstand the temperature effect of 
the incinerator.
It should house the ignition burner time, feed interval timer, shutdown timer post combustion 
chamber temperature controller, control for burner, blower fans and gas washer. 
Digital display of temperature and set timing parameters. 
Emergency shutdown button for shutting all burners and blowers in case of emergency. 
All design and installation must be in accordance with electrical safety rules. 
Electrical inputs available single phase 220 V, 50 Hz:  Three Phase 400 Volts ± 10 %. 
Smokeless emission for all the running time. 7,000 each Total Qty 21,000
 Mask for order(May be provided locally)
Incinerator Operator Costume Note:
All following accessories of operator may be provided locally
04 x Fire protective complete dress for operators 
10 x Pairs of leather gloves for hospital waste handling staff. 
10 x Pairs of long rubber shoes for hospital waste handling staff